Customization: | Available |
---|---|
Material: | Customizable |
Size: | Customizable |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Water tank is a device used to store and distribute liquids, which is widely used in life and industry. Water tanks come in many types, and can be divided into fiberglass tanks, stainless steel tanks, enamel tanks, galvanized steel tanks, and PE tanks according to their materials. Each type of water tank has its own unique characteristics and applicable scenarios.
Shandong Wanze Shengshi Environmental Protection Technology Co., Ltd. Smart Fire Integrated Pump Station (Buried Type) List | |||||
Serial number | Classification | Name and specification model | performance | unit | quantity |
1 | Pump station body | Smart fire protection integrated non-floating pump station:) | SW composite box, third generation enhanced module, assembled, no welding required, factory production, on-site bolt assembly, standard construction, convenient and fast. | seat | 1 |
1-1 | Smart fire protection integrated non-floating pump station top-entry pump room: | The SW box and door-type steel structure are hot-dip galvanized for anti-corrosion treatment, and high-strength bolts are installed on-site to resist corrosion. | tower | 1 | |
1-2 | Smart fire protection integrated non-floating pump station water tank: | The SW box body is assembled with bolts, the top plate is 3.0mm galvanized plate; the side plate is 3.0mm composite plate, which is composed of hot-dip galvanized steel plate and 304 stainless steel, and is molded and stretched to ensure water quality; there are special support rods inside the water tank, and the support rods are connected with special detachable connectors, which have high strength and long service life. | tower | 1 | |
1-3 | Rail type manhole cover | MXRG-2300 (patented technology) Size: 2m*2m; integral sliding cover, easy to open and close, sealed and waterproof | indivual | 1 | |
1-4 | Water inlet integrated control device | Adjust the water inlet of the water tank and also play a role in water leakage protection | set | 2 | |
1-5 | Combined corner right angle steel staircase | MXZT-200 with corner platform | tower | 1 | |
1-6 | Sump protection device | MXF | indivual | 1 | |
1-7 | Pre-buried pipe | MXY-1.3M | set | 3 | |
1-8 | Steel structure prefabrication | Portal steel structure, main beam: 32# I-beam and above, column: 16# I-beam; ground support is strictly prohibited inside the pump room to ensure maintenance space and emergency passage. The load-bearing parts of the structure are hot-dip galvanized for corrosion protection, and bolts are assembled on site to prevent welding and other connection methods that damage the surface anti-corrosion coating. | set | 1 | |
1-9 | Beam I-beam 32# | On-site bolt assembly, eliminating the use of welding and other connection methods that damage the surface anti-corrosion coating | set | 1 | |
1-10 | Secondary beam I-beam 14# | On-site bolt assembly, eliminating the use of welding and other connection methods that damage the surface anti-corrosion coating | set | 1 | |
1-11 | Column I-beam 16# | On-site bolt assembly, eliminating the use of welding and other connection methods that damage the surface anti-corrosion coating | set | 1 | |
1-12 | Beam channel steel 12# | On-site bolt assembly, eliminating the use of welding and other connection methods that damage the surface anti-corrosion coating | set | 1 | |
1-13 | I-beam connecting plate | Q235-10mm board | set | 1 | |
1-14 | Assembly labor, auxiliary materials and accessories | square | 20 | ||
1-15 | Mechanical exhaust device | MXZ ventilator (with insect screen | Only | 2 | |
1-16 | Electronic level gauge | Submersible level transmitter, local data display and remote data transmission | set | 1 | |
1-17 | Fire extinguisher | Portable ammonium phosphate | tower | 2 | |
1-18 | Bridge | Electrostatic spraying shell, anti-corrosion and moisture-proof | set | 1 | |
1-19 | Grounding device | set | 1 | ||
2 | Pump sets and related equipment | Fire booster water pump set | The water pump adopts a vertical pump, which is dry-installed for easy maintenance; the self-priming water suction method is in full compliance with the specifications. | set | 1 |
2-1 | Smart fire hydrant pump set | Strictly in accordance with the requirements of GB50974-2014 technical specifications, the integrated production water pump parameters are Q=20L/S, H=0.50MPa, N=18.5Kw | tower | 2 | |
2-2 | Pressure dual control and protection system | Collect pressure signals, control equipment operation, and provide overpressure and low pressure protection | set | 1 | |
2-3 | Sewage pump | Q=11.1L/S, H=20m ,N=4kW | tower | 2 | |
2-4 | Fully automatic dehumidifier | HD601A | tower | 1 | |
2-5 | Piston type water hammer absorber | Avoid damage to equipment caused by water hammer | set | 1 | |
3 | Booster pipes, valves and other accessories | Fire protection pipeline | Pipes and valves are connected by clamps. They are integrated and tested in the factory. They can be used after connecting to the water outlet. The accessories meet national standards. | set | 1 |
3-1 | Hot dip galvanized steel pipe | Configure according to the corresponding standards | set | 1 | |
3-2 | Flow Meter | Select flow meter with high precision, stable performance and strong anti-interference. | set | 1 | |
3-3 | Pressure relief valve | When the pipeline pressure exceeds the set pressure, it will automatically open for rapid pressure relief to protect the safety of the pipeline. | set | 1 | |
3-4 | Turbine flange butterfly valve | Good sealing and strong anti-freeze performance. | set | 1 | |
3-5 | Rising stem gate valve | Achieve good sealing effect, open and close quickly and reliably. | set | 1 | |
3-6 | Silencer Check Valve | It has good antifreeze performance, high strength, and can prevent water hammer. | set | 1 | |
3-7 | Ball Check Valve | set | 1 | ||
3-8 | Rubber joints | High quality rubber, good sealing performance | set | 1 | |
3-9 | Vacuum pressure gauge | M20*1.5 -0.1~0.15MPa | set | 1 | |
3-10 | Pressure gauge | M20*1.5 0~1.6MPa | set | 1 | |
3-11 | Digital pressure gauge | M20*1.5 0~1.6MPa | set | 1 | |
3-12 | Water absorption main pipe | DN400 gate valve + pipeline | set | 1 | |
3-13 | Pipeline connection | Clamps, clamp elbows, clamp flanges, clamp tees, bolts, etc. | set | 1 | |
3-14 | Water pump base | Material: hot-dip galvanized steel to ensure strength; | set | 1 | |
4 | Control System | Intelligent control system | Control cabinet model: MXK-2-18.5kw; the control cabinet is built in the pump room, and the operating data can be recorded and called | set | 1 |
4-1 | Programmable logic controller unit | Logic control, data acquisition, calculation, storage, input and output processing, and communication coordination | Only | 1 | |
4-2 | Human Machine Interface | Highly sensitive 7-inch touch screen, integrated Ethernet port, faster communication speed than ordinary RS485 port, strong anti-interference ability | set | 1 | |
4-3 | Dual power converter | The main and backup power supplies fail to switch to each other to avoid power outages | set | 1 | |
4-4 | Other low voltage components | Select famous and high-quality brands, with stable performance and strong overload capacity. | set | 1 | |
4-5 | Cabinet | The Q235 material is 2.0mm thick and electrostatically sprayed, which is anti-corrosion and moisture-proof; the dedicated organic glass panel is convenient for observation. | set | 1 | |
4-6 | Water pump wire connection | Flame retardant cable ZR-YC | set | 1 | |
5 | Functional modules | Smart Fire Management System | Collect our equipment data information to the cloud, and use the platform data analysis function to systematically manage the current status of the equipment. | set | 1 |
5-1 | Overflow alarm system | When the water level in the pump room is higher than a certain level, the system will send out an audible and visual alarm to remind the equipment manager to deal with the abnormality in time. | set | 1 | |
5-2 | Automatic pump start function | The fire protection standard provides for automatic pump start function when the pressure boosting pipeline is low pressure and the flow rate in the pressure stabilizing pipeline is large. | set | 1 | |
5-3 | Pump room sewage control system | The sewage system in the pump room of the buried pump station ensures the safety of the pump room equipment. | set | 1 | |
5-4 | Fire forced start system | If the equipment does not start when there is a fire signal, the water pump can be started by the forced start system. | set | 1 | |
5-5 | Mechanical emergency start system | When the equipment fails to operate, the mechanical emergency start system can be used to start the water pump to ensure pipeline pressure. | set | 1 | |
5-6 | Anti-misoperation system | Set thresholds for equipment management operations to prevent non-relevant personnel from operating the equipment and causing equipment abnormalities. | set | 1 | |
5-7 | Reserved remote interface | The programmable controller opens a port through which the remote terminal can collect and summarize device data information. | set | 1 | |
5-8 | Lightning protection and grounding protection system | The control system and equipment contain surge protection systems to reduce the impact of large currents on the equipment. | set | 1 | |
5-9 | Phase sequence protection system | The control system contains a phase sequence protection device, which alarms for abnormal power supply to prevent the abnormal power supply from affecting the equipment. | set | 1 | |
5-10 | Water pump integrated protection system | Comprehensively protect the running status of the water pump motor, including phase loss, phase disorder, leakage, overheating, etc. | set | 1 | |
6 | Fire pump system | Fire pump | Vertical single-stage pump, XBD4.5/15G-L, flow 15L/S, head 45m, power 11kw | tower | 2 |
6-1 | Control cabinet | Matching fire water pump, ZHK-XFYJ-11, one control two direct start including mechanical emergency device; protection level: IP55, cabinet size 1400*700*480mm | seat | 1 | |
7 | Fire stabilizing system | Air pressure tank | Diaphragm air pressure tank SQL600*1.0 | seat | 1 |
7-1 | Pressure regulating pump | Pressure-stabilizing pump XBD3.2/1.1GL, flow rate 1.1L/S, head 32m, power 1.5kw | tower | 2 | |
7-2 | Other Packages | Carbon steel pipe accessory base | set | 1 | |