Environmental conditions and requirements for biogas
The biogas generator set can operate stably and reliably under environmental conditions of -40ºC~+40ºC, relative humidity <90% (at 25ºC), and altitude ≤1000m. Under standard environmental conditions (atmospheric pressure 100KPa, ambient temperature: 25ºC, relative humidity 30%), the gas quality meets the standard conditions and can output rated power. Unit requirements for biogas
Within 1m of the unit's gas inlet pressure regulating valve,
1. Biogas temperature ≤40ºC;
2. Biogas pressure 3~10kPa, pressure change rate ≤1kPa/min;
3. The volume content of methane in biogas is not less than 40%, and the change rate is ≤2%/min;
4. H2S ≤20mg/Nm3;
5. NH3 ≤20mg/Nm3;
6. Impurity particle size ≤5μm, impurity content ≤30mg/Nm3;
7. Moisture content in biogas ≤40g/Nm3.
Special instructions are required for biogas with a methane volume content of ≤50%.
If the sulfur and ammonia content in the combustible gas is high, it will not only seriously corrode the spark plug electrode, but also increase the acid value in the engine oil, corrode the internal parts of the unit, and easily generate sediment, increasing corrosion and wear to the engine.
2. Main specifications of the generator set | ||||
Generator model | LX - 80GF | Rated current | 144 A | |
Rated Power | 80 kW | Power Factor | 0.8 | |
Reserve power | 100 kVA | Controller | Automatic PLC control | |
Rated voltage | 400V/230V | Speed regulation mode | Electronic speed control | |
Rated frequency | 50Hz | Type | Open | |
Rated speed | 1500 rpm | Biogas /gas consumption rate | 0.6 /0.3 m³/Kw·h | |
* Altitude <1000 meters, ambient temperature <40 ºC , ambient humidity ≤60%. * Rated power: The maximum power of the generator set when it is continuously operated with variable load and with unlimited operating hours per year under the agreed operating conditions and maintenance as specified by the manufacturer. The average power output during a 24-hour operating cycle should not exceed 70% of the rated power, in accordance with GB/T2820-97 (eqv ISO8528) . * Standby power: The generator set can be overloaded on the basis of continuous power for 1 hour every 12 hours within a certain period of time. 10%, the unit power at this time is the standby power. * Rated voltage: 380/220V , 400/230V , 415/240V , 440/254V and other voltages can be customized. |
4. Engine technical parameters | |
Engine Model | Huadong 6126D-NG |
Rated Power | 82KW |
Cylinder Type | In-line, four-stroke |
Rated speed | 1500 rpm |
Number of cylinders | 6 cylinders |
Bore x stroke | 12 6 × 1 30 mm |
Displacement | 10L |
Startup Mode | Electronic start |
Compression ratio | 11.5:1 |
Crankshaft rotation direction | Counterclockwise (from the flywheel direction) |
Cooling method | Water Cooling |
Air intake method | Naturally Aspirated |
Gas mixing method | Premix |
Speed regulation mode | Electronic speed control |
Biogas /gas consumption | 0.6 /0.3 m³/Kw·h |
Lubricating oil pressure | 345-483 Kpa |
Exhaust temperature | 580 ºC |
5. Generator technical parameters | ||||
Generator brand | Brushless generator | Insulation class | Class H | |
Rated Power | 80 kW | Wiring method | Three-phase four-wire | |
Reserve power | 100KVA | Cooling method | Air Cooling | |
Rated current | 144 A | Protection level | IP2 3 | |
Power Factor | 0.8 | Voltage adjustment method | AVR Automatic Voltage Regulation | |
Excitation type | Brushless self-excitation | Voltage adjustment range | ≥±5% | |
Voltage regulation rate | ±1.0% | Connection method | Single bearing |
Strict inspection and testing, using advanced instruments to conduct comprehensive testing of the generator sets required by your company, to ensure that the performance indicators of the products meet your company's requirements. The company will explain our company's technical information in a comprehensive and detailed manner.
The warranty period is 12 months or 1500 hours of operation, whichever expires first. If quality problems occur during the warranty period and it is confirmed that the problem is caused by our generator set rather than external or natural causes (refer to various natural disasters, transportation, loading and unloading, wrong operation, etc.), we will provide the relevant spare parts for maintenance free of charge. After the warranty period, we can provide you with the required spare parts at cost price.